Part Number Hot Search : 
HY5DU KE200 00005 25JE7TS 2F4255 1N974B 1N4745A 20400
Product Description
Full Text Search
 

To Download 1626-1-15A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 description typical applications current ratings, typical voltage drop values and colour coding technical data single pole, thermal miniaturised circuit breaker designed for automotive applications. fits into fuse blocks designed to iso 8820-3, type f. automatic reset (for dc 12 v only) and open circuit (modified reset to sae) version optional. open circuit version ensures contacts staying open as long as power is on. the circuit breaker will reset after the load is removed. particularly suitable for installation in inaccessible locations. current ratings correspond to those of blade fuses. clear colour coding of the ratings: blade fuse and circuit breaker of the same colour have the same rating. breakers rated 7.5 a through 30 a have a fast characteristic curve and only hold 70 % of their rated current continuously. us patent number: us 8,576,042,b2 protection of electrical systems of passenger cars, trucks, buses, watercraft, extra low voltage wiring systems. 1626-1/-2 1626-3 1626-3h voltage rating 1626-1/-2: dc 12 v 1626-3/-3h: dc 12 v, dc 24 v max. voltage rating 1626-1/-2: dc 14.5 v 1626-3/-3h: dc 29.0 v current ratings 5...30 a 5 a: medium characteristic curve 7.5...30 a: fast characteristic curve service short-circuit breaking capacity 300 operations at 2 x i n ambient temperature -40...+85 c (-40+185 f) (for higher temperatures please enquire) reset period for 1626-1 (at 23 c) 15 s reset period for 1626-2 (at 23 c) after 5 sec at rated voltage < 35 s degree of protection (iec 60529) operating area ip40 (-3) operating area ip50 (-1, -2) terminal area ip00 ultimate short-circuit breaking capacity 3 break operations at 150 a, or 1 break operation at 2,000 a vibration 10 g (57-500 hz), 0.38 mm (10-57 hz) to iec 60068-2-6, test fc 10 frequency cycles/axis sae-j553, step no. 14, 4.2.7.1.5 shock 50 g (11 ms) to iec 60068-2-27, test ea sae-j553, step no. 14, 4.2.7.1.6 corrosion 96 hrs in 5 % salt mist, to iec 60068-2-11, test ka sae-j553, step no. 14, 4.2.7.1.3 humidity 240 hrs in 95 % rh, to iec 60068-2-78, test cab sae-j553, step no. 14, 4.2.7.1.2 mass approx. 3 g caution: it is good practice to switch off the vehicles ignition system before manually releasing or re-setting the circuit breaker. free travel of the reset button must be ensured! please ensure to push in the actuator smoothly and completely. all dimensions without tolerances are for reference only. in the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. product markings may not be exactly as the ordering codes. errors and omissions excepted. ordering information type no. 1626 single pole thermal mini-cbe with standard characteristic curve version, according to sae j553 1 type 1, dc 12 v automatic reset 2 type 2, dc 12 v modified reset 3 type 3, dc 24 v with reset button 3h type 3*, dc 24 v with reset button and manual release facility current ratings 5 7.5 10 15 20 25 30 a 1626 - 1 - 10 a ordering example current rating (a) voltage drop (mv) housing cap colour 5 < 150 light brown 7.5 < 150 brown 10 < 150 red 15 < 150 blue 20 < 150 yellow 25 < 150 white 30 < 150 light green thermal automotive mini-cbe 1626-... www.e-t-a.de 1646 1
2 the time/current characteristic curve depends on the ambient temperature prevailing. in order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. see also section technical information. ambient temperature f ambient temperature c -40 -40 -22 -30 -4 -20 +14 -10 +32 0 +50 +10 derating factor 0.73 0.78 0.82 0.86 0.91 0.95 ambient temperature f ambient temperature c +73.4 +23 +104 +40 +122 +50 +140 +60 +158 +70 +185 +85 derating factor 1 1.09 1.16 1.25 1.33 1.43 1 1 1 1 1 1 1 1 1 1 1 1 4 6 1 4 6 1 4 4 6 1 46 1 4 1626-1 / 1626-2 2.8 .110 0.8 .032 7 .276 3.8 .149 10.9 .429 12.7 .500 4.5 .177 germany 13.3 .524 2.8 11.6 .457 10.4 .409 .295 7.5 2 .079 25 .984 1626-3 2 .079 0.8 0.5 on .031 .019 on 4.5 0.5 off .177 .019 off 3.5 .138 0.6 .024 1.8 .071 germany 13.3 .524 11.6 .457 2 .079 25 .984 1626-3h 3.5 .138 13.3 .524 7 .275 4.8 .189 30.2 1.19 0.8 0.5 on .031 .019 on 25 .984 4.5 0.5 off .177 .019 off 11.6 .457 germany 1 2 1626-1 1 2 1626-3 1 2 1626-3h 1 2 1626-2 dimensions internal connection diagrams typical time/current characteristic curve at +23 c / +73.4 f this ist a metric design and millimeter dimensions take precedence ( mm inch) thermal automotive mini-cbe 1626-... www.e-t-a.de 1646 1


▲Up To Search▲   

 
Price & Availability of 1626-1-15A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X